IP65 Fluorescent Emergency Light IP65 FLUO 2x17W 2x32W
Housing made of reinforced polyester glass fiber (GRP)
High transparent and impact resistant PC diffuser
Both standard and emergency modes available
Operation and survive in extremely cold temperature down to minus 40 degrees (-40°C /-40°F)
UL electronic ballast, EEI=A2
IP65 rating
2X17W
Item No. | FL02H218-4 | FL02I218-4 | FL02H218-4-H | FL02J218-4 |
GE part number | 109W1982P001 | 109W1982P002 | 109W1982P003 | 109W1982P004 |
Characteristics | 2ft Light, Standard,Standard Weather (SW) | 2ft Light, Emergency Backup, SW | 2ft Light, Heater, Cold Weather (CW) | 2ft Light, Emergency Backup and Heater, CW |
Lamp type | Fluorescent Lamp T8 2×17W | |||
Rated voltage | 120-277VAC 50/60Hz | 120/277VAC 50/60Hz | 120/277VAC 50/60Hz | 120/277VAC 50/60Hz |
Input power | 34W | 34W | 34W | 34W |
- | - | 74W (Heater Works) | 74W (Heater Works) | |
Input current | 0.12-0.27A | 0.13-0.28A | 0.12-0.27A | 0.13-0.28A |
- | - | 0.27-0.62 (Heater Works) | 0.27-0.62 (Heater Works) | |
Power factor | >0.98 | >0.95 | >0.98 | >0.95 |
Battery voltage | / | 1.8Ah, 4.8V | / | 1.8Ah, 4.8V |
Charging time | / | 24H | / | 24H |
Discharge time | / | >90 minutes | / | >90 minutes |
Operation temperature | -15~50℃ | -15~50℃ | -30~50℃ | -30~50℃ |
Survival temperature | -20~60℃ | -20~60℃ | -40~60℃ | -40~60℃ |
Lumen output | 1800 LM | |||
Battery life time | / | 5 years | / | 5 years |
Abnormal protection | short-circuit Protection with auto-reset | |||
Applicable standards | UL1598; CAN/CSA 22.2 No.250.0 and the Canadian country-specific requirements |
2X32W
Item No | FL02H236-4 | FL02I236-4 | FL02H236-4-H | FL02J236-4 |
GE part number | - | - | 108W9547P003 108W9547P007 | 108W9547P001 108W9547P002 |
Characteristics | 4ft Light, Standard,Standard Weather (SW) | 4ft Light, Emergency Backup, SW | 4ft Light, Heater, Cold Weather (CW) | 4ft Light, Emergency Backup and Heater, CW |
Lamp type | Fluorescent Lamp T8 2x32W | |||
Input voltage | 120-277VAC 50/60Hz | 120/277VAC 50/60Hz | 120/277VAC 50/60Hz | 120/277VAC 50/60Hz |
Input power | 64W | 70W | 64W | 70W |
- | - | 104W (Heater Works) | 110W (Heater Works) | |
Input current | 0.23-0.53A | 0.25-0.58A | 0.23-0.53A | 0.25-0.58A |
- | - | 0.38-0.86A (Heater Works) | 0.40-0.91A (Heater Works) | |
Power factor | >0.98 | >0.95 | >0.98 | >0.95 |
Battery voltage | - | 1.8Ah, 4.8V | - | 1.8Ah, 4.8V |
Charging time | - | 24H | - | 24H |
Emergency time | - | >90 minutes | - | >90 minutes |
Operation temperature | -15~50℃ | -15~50℃ | -30~50℃ | -30~50℃ |
Survival temperature | -20~60℃ | -20~60℃ | -40~60℃ | -40~60℃ |
Lumen output | 3600 LM | |||
Battery life time | - | 5 years | - | 5 years |
Abnormal protection | short-circuit Protection with auto-reset | |||
Applicable standards | UL1598; CAN/CSA 22.2 No.250.0 and the Canadian country-specific requirements |
FL02H218-4/FL02H236-4: Standard Luminaire, with UL approved Philips electronic ballast
FL02H218-4-H/FL02H236-4-H: Standard + Heater Luminaire, with UL approved Philips or equivalent brand electronic ballast and automatic heating system
FL02I218-4/FL02I236-4: Emergency Luminaire, with UL approved electronic ballast and emergency module
FL02J218-4/FL02J36-4: Emergency + Heating Luminaire, with UL approved electronic ballast, emergency module and automatic heating system
Phenix Emergency module (type No.184000/184010) is UL approved. Battery pack is replaceable.
The automatic heating system is used to ensure the luminaire to work well under arctic weather condition. The heating system will start working automatically when the internal temperature of the luminaire is on or l below 5℃ +/-4℃ and will stop working when the temperature reaches up to 20℃ +/-3℃.
GE product description added (without fluorescent lamps):
109W1982P001:120V/60Hz-Standard Luminaire, 2pcs M20 cable glands
109W1982P002:120V/60Hz-Built in emergency battery function, 90minutes, 2pcs M20 cable glands
109W1982P003:120V/60Hz-Built in heater, 2pcs M20 cable glands
109W1982P004:120V/60Hz-Built in emergency battery function, 90minutes, heater, 2pcs M20 cable glands
109W1982P101:Fluorescent lamp T8, 17W
108W9547P001:120V/60Hz-Built in emergency battery function, 90minutes, heater, 1pc M20 cable gland
108W9547P002:120V/60Hz-Built in emergency battery function, 90minutes, heater, 2pcs M20 cable glands
108W9547P003:120V/60Hz-Built in heater, 2pcs M20 cable glands
108W9547P007:120V/60Hz-Built in heater, 1pc M20 cable gland
1 or 2PCS M20 cable gland on each side
1PC M20 punching hole on other side
PC plastic or stainless steel clips with anti-falling off structure
FL02H218-4/FL02I218-4/ FL02H218-4-H/FL02J218-4:
Mounting distance: 400mm
2pcs mounting holes ready for M6 crosshead or inner hexagon head bolts.
Ceiling or wall mounting:
FL02H236-4/FL02I236-4/ FL02H236-4-H/FL02J236-4:
Z brackets, 4 holes M4 for the Z brackets)
Input Voltage: 120/277VAC
Input Voltage: 120/277VAC
Input Voltage: 120/277VAC
Wind power system
Ships
Freezers
Any other harsh indoor and outdoor locations